Tripp Lite
Tripp Lite SRCOOLDXRW25 Cooling Systems Indoor In-row Air Conditioning Unit 037332250681
Tripp Lite SRCOOLDXRW25 SpecsBuy Tripp Lite SRCOOLDXRW25 Cooling SystemsShop Cooling SystemsCheap 037332250681Top Image Tripp Lite SRCOOLDXRW25 Cooling SystemsDeals Tripp Lite SRCOOLDXRW25 Cooling Systems

Part Number: SRCOOLDXRW25
Condition: New
In Stock: Manufacturer Drop Ship 
Real time availability   


Regular:$45,374.00
Save:$20,563.30 (45%)

Your Price:
$24,810.70

As low as $2274/month
Buy Now, Pay Later



  • Shipping Insurance
  • Price Match Guarantee
  • Terms of Service Guarantee
  • Identity Theft Protection
FREE with your purchase
Expert Name, Expert Title
Let our Specialist make your purchase easier

Also Available

Product Specifications



Eaton In-Row Precision Cooling System - 25.8 kW (88,000 BTU), 3PH, 208V, 42U, 300mm - In Row Air Conditioner for Server Rooms SRCOOLDXRW25

IN-ROW PRECISION COOLING SYSTEM 25 KW 85,000 BTU 208-240V 42U

Manufacturer Part Number: SRCOOLDXRW25



CPN:IN-ROW PRECISION COOLING SYSTEM 25 KW 85,000 BTU 208-240V 42U
MANUFACTURER NAME: Tripp Lite
MANUFACTURER PART NUMBER: SRCOOLDXRW25
UPC EAN CODE: 037332250681
LANGUAGE: EN
MARKET:US

General Information:

Slim Air Conditioning System Saves Space While Delivering Primary Precision Cooling
This SmartRack® in-row precision air conditioning system is the ideal cooling option for your small-to-medium data center, IT room or other edge location. Typical CRAC/CRHC units are too large for these locations, but the SRCOOLDXRW25 cools your mission-critical equipment while occupying very little floor space, supporting up to 25.8kW (88,000 BTU/hr) of heat load per unit. The cabinet is just 300 millimeters wide, making it easy to position optimally within a row for precision close-coupled cooling. It requires the same front and rear clearance as a standard rack enclosure.

Uses DX Technology to Deliver Cool Air to Loads
This direct expansion (DX) cooling system pulls unconditioned air through the rear of the unit, cools it with condensed refrigerant and delivers it to equipment loads with up to 88,000 BTU/hr and nearly 2,950 CFM airflow. EC fans and a variable speed compressor provide variable airflow and constant temperature based on room conditions.

High Cooling Efficiency Saves You Money
Inverter compressor and EC fan technology automatically regulate cooling output to match heat load and conserve energy during off-peak hours, lowering your overall energy costs and lengthening the lifespan of the equipment being cooled. The close-coupled design captures heat at the source to improve energy efficiency by 25% over traditional perimeter CRACs. In addition, the SRCOOLDXRW25 is ideally sized for your small-to-medium data center at virtually any density, saving you the cost of a raised floor or an overbuilt/overprovisioned CRAC unit. It uses eco-friendly R410A refrigerant, reflecting your commitment to environmental responsibility.

Easy to Operate with the Color Touchscreen
You have total control over the SRCOOLDXRW25 using the front-panel color touchscreen interface, which lets you monitor and access system configuration and status information. A built-in controller detects and manages data center temperatures, automatically adjusts cooling levels and supports various control modes. Intelligent temperature control and variable speed technology allow precise airflow and temperature adjustment to match specific load requirements closely without wasting energy on overcooling.

Reconfigure Your Cooling Needs as Your Equipment Needs Change
The modular, in-row cabinet design easily facilitates expansion or movement on its built-in casters, allowing your increasing cooling needs to be reconfigured as your data center grows. A simple redundancy model (N+1) is built in as part of the number of scalable units to be deployed.

Pre-Installed WEBCARDLXMINI Network Interface Offers 24/7 Access
Remote access to the SRCOOLDXRW25 can save you the time and expense of having someone constantly on-site. The built-in WEBCARDLXMINI lets you manage temperatures, receive alerts, review logs and control settings 24/7 via HTTP(S), menu/CLI via SSH/Telnet and SNMP for integration with management software platforms such as DCIM. The ability to configure settings and monitor alarms off-site can bolster your bottom line.

ManufacturerTripp Lite by Eaton
Manufacturer Part NumberSRCOOLDXRW25
Manufacturer Website Addresshttps://tripplite.eaton.com/
Brand NameTripp Lite by Eaton
Product ModelSRCOOLDXRW25
Product NameIndoor In-row Air Conditioning Unit
Product TypeCooling System
  Product UPC037332250681
Physical Characteristics:
Color FamilyBlack
Product ColorBlack
Product MaterialAluminum
Steel
Height78.7"
Width11.8"
Depth43.3"
Weight (Approximate)437 lb
Miscellaneous:
What's in the box
  • Indoor In-row Air Conditioning Unit
  • Outdoor Condenser
  • Side Discharge Panels / Adapters
  • Hardware Kits
  • Owner's Manual
Application/UsageServer
Country of OriginChina
Environmentally FriendlyYes
Environmental ComplianceRestriction of Hazardous Substances (RoHS)
Warranty:
Warranty1 Year

Date Inserted: Tuesday February 7, 2023

This product was last updated on Tuesday November 5, 2024

All products are brand new and factory sealed unless otherwise stated.
 *** Disclaimer- Information is supplied by the Manufacturer. The image, including color, may differ from actual product appearance. CompSource, Inc. is not responsible for data. ***

Questions and Answers

Questions and Answers

Ask CompSource

Shipping / Returns

Shipping

Requires Truck = $279.00
Additional lift gate fee's may apply.

This item is currently available direct from the manufacturer. Normal fulfillment is 7-21 business days, but can vary depending on the item. Refurbished items can take longer depending on availability of the product. Once purchased, you will be on a waiting list. Automated tracking may not be updated on our site for either of these scenarios, please contact a representatives for more information regarding a particular product.

Shipping dates are best estimates based on product location and may vary with holidays.

If product requires trucking, additional fees may apply.

* Some destinations are subject to Applicable State/Duty Taxes

Returns

CompSource realizes that every product may have different return guidelines. Please see the policy below regarding this item.

Please Note: Due to Tripp Lite's Policy this product is not available for return or exchange and must be handled with Tripp Lite Direct.

For support on this product, please contact Tripp Lite.  www.tripplite.com


Tripp Lite Company's Information

Tripp Lite  
Click Tripp Lite for all products

Local #: 773-869-1234

Tech Support #: 773-869-1234

Site:  www.tripplite.com

Accessories

Product Reviews

Overall Rating | Write a Review

    Best Sellers
    More Best Sellers

    Recently Viewed

    About Tripp Lite

    At Tripp Lite, we believe that quality power protection and connectivity solutions are essential for businesses and individuals alike. With over 95 years of experience in the industry, we have developed a reputation for providing reliable, innovative products at affordable prices.

    Why buy from Tripp Lite?

    1. Reliability: Our products are designed and manufactured to the highest standards, ensuring they will keep your devices and systems protected and running smoothly.

    2. Innovation: We are constantly innovating and developing new technologies to meet the changing needs of our customers.

    3. Customer service: We pride ourselves on providing excellent customer service, with knowledgeable staff available to help you with any questions or issues you may have.

    4. Affordable prices: We offer competitive prices without sacrificing quality, making our products a great value for your money.

    5. Comprehensive product range: We offer a wide range of products, from surge protectors and power strips to UPS systems and connectivity solutions, to meet the needs of businesses and individuals.

    About us:

    Tripp Lite was founded in 1922 as a manufacturer of electrical components and has since grown into a leading provider of power protection and connectivity solutions. Our products are used by businesses, government agencies, schools and other organizations around the world.

    We are committed to providing our customers with high-quality, reliable products backed by excellent customer service. We strive to be the go-to source for all your power protection and connectivity needs.


    CompSource can solution sell power and Tripp Lite is one of manufacture we have a lot of knowledge and history with. Please checkout some of the most popular Tripp-Lite categories we offer;

    Learn more about Cooling Systems

    Introduction: Air conditioning plays a critical role in maintaining optimal temperatures for data centers and server closets, where sensitive electronic equipment generates heat continuously. In this educational piece, we will delve into the specific considerations and requirements for air conditioning in data centers and server closets to ensure efficient cooling and reliable operation.

    1. Importance of Proper Cooling: Data centers and server closets house a significant amount of electronic equipment that generates heat during operation. Maintaining appropriate temperatures is crucial for the performance, longevity, and reliability of the equipment. Excessive heat can lead to equipment failure, reduced efficiency, and potential data loss.

    2. Cooling Systems for Data Centers and Server Closets: a. Precision Air Conditioning (PAC): PAC systems are designed specifically for data centers and server rooms. They provide precise temperature and humidity control through advanced cooling techniques, such as direct expansion or chilled water systems. PACs offer better control, redundancy, and scalability to meet the unique cooling demands of these environments.

    b. Computer Room Air Conditioning (CRAC): CRAC units are commonly used in larger data centers. They operate similarly to PAC systems but are typically larger in capacity and often incorporate additional features like hot aisle/cold aisle containment for improved efficiency.

    c. In-Row Cooling: In-row cooling systems are strategically placed close to the server racks, providing localized cooling. These systems offer better efficiency, reduced energy consumption, and easier scalability.

    1. Factors to Consider: When selecting and implementing air conditioning for data centers and server closets, the following factors should be considered:

    a. Heat Load Calculation: Accurate heat load calculation is essential to determine the cooling capacity required to maintain appropriate temperatures. Factors like equipment density, power consumption, and future growth should be considered.

    b. Redundancy and Resilience: Data centers require redundancy in cooling systems to ensure uninterrupted operation. Implementing redundant systems, backup power supply, and appropriate maintenance plans are vital to avoid downtime and equipment failures.

    c. Airflow Management: Proper airflow management is crucial to maximize cooling efficiency. Hot aisle/cold aisle containment, optimized rack layouts, and effective use of air distribution systems help to minimize hot spots and ensure uniform cooling.

    d. Energy Efficiency: Data centers consume substantial amounts of energy, and optimizing energy efficiency is paramount. Consider energy-efficient cooling solutions, such as variable speed fans, economizers, and energy management systems, to reduce power consumption and associated costs.

    1. Maintenance and Monitoring: Regular maintenance and monitoring are essential for the reliable operation of cooling systems in data centers and server closets. Key practices include: a. Cleaning air filters and coils to ensure optimal airflow. b. Regular inspections for leaks, proper refrigerant levels, and electrical connections. c. Monitoring temperature and humidity levels to identify and address any anomalies promptly. d. Implementing proactive maintenance plans and partnering with qualified HVAC professionals.

    Conclusion: Proper cooling is a critical aspect of maintaining optimal conditions in data centers and server closets. By understanding the specific requirements, selecting suitable cooling systems, implementing proper airflow management, and adhering to regular maintenance practices, data center operators can ensure efficient cooling, equipment reliability, and the longevity of their valuable electronic assets.

    I've purchased from CompSource in the past and was thoroughly please with all aspects of ordering process, but especially with the care that was taken in the packing of my order! icee2000
    More Reviews

    eStores

    Connect With Us