Portable Ac Unit For Server Rooms - 24,000 Btu (7 Kw), 208/240v, Not For Sale In SRCOOL24K
SRCOOL24K | Tripp Lite®
Part Number: SRCOOL24K
Condition: New
In Stock: 124
Real time availability
Product Specifications
Portable Ac Unit For Server Rooms - 24,000 Btu (7 Kw), 208/240v, Not For Sale In SRCOOL24K
PORTABLE AC UNIT FOR SERVER ROOMS - 24,000 BTU (7 KW), 208/240V, NOT FOR SALE IN
Manufacturer Part Number: SRCOOL24K
Features
- Produces 24,000 BTU/h(7 kW) of cooling capacity in a portable, rack-width chassis
- Prevents equipment shutdowns, malfunctions and failures caused by overheating and temperature fluctuations
- Filters and dehumidifies the air to enhance equipment performance
- Uses environmentally friendly R410A refrigerant, which complies with worldwide standards
- Efficient close-coupled cooling reduces energy use and operating costs
Convenient Operation
- Adjustable louvers support area cooling applications
- Flexible dual output ducts aim cold air where it’s needed, such as an overheated rack enclosure or equipment hot spot
- Supports unattended shutdown and startup, including automatic restarts after power failures
- Easy-to-read control panel with digital display and diagnostic LEDs for local management
- System-lock function disables all other buttons to prevent accidental input
Advanced Network Monitoring
- Included SRCOOLNET2 accessory allows remote monitoring of temperatures, alerts, logs and control settings from anywhere via SNMP, web browser, SSH or telnet
- ENVIROSENSE remote sensor monitors temperature and humidity up to 12 ft. away
Easy to Install
- Rolls into place on built-in casters
- Fits into 2 x 2 ft. section of floor space
- 6.5 ft. power cord with NEMA L6-20P plug connects to a standard 208/240V 20A AC outlet
- No external condenser, refrigerant piping or professional maintenance required
- Built-in evaporator expels condensation through exhaust tube—no floor drain or water collection tank needed
- Exhaust kit removes hot air from room through drop ceiling, window or return duct
- Includes all parts required for setup
MANUFACTURER NAME: Tripp Lite
MANUFACTURER PART NUMBER: SRCOOL24K
UPC EAN CODE: 037332184856
LANGUAGE: EN
MARKET:US
Questions and Answers
Questions and Answers | Ask CompSource |
Shipping / Returns
Shipping
Requires Truck = $279.00
Additional lift gate fee's may apply.
Shipping dates are best estimates based on product location and may vary with holidays.
If product requires trucking, additional fees may apply.
* Some destinations are subject to Applicable State/Duty Taxes
Returns
CompSource realizes that every product may have different return guidelines. Please see the policy below regarding this item.
This Product Has Limited Exchange Privileges.
Limited returns within 30 days of purchase permitted on this product.
For support on this product, please contact Tripp Lite. www.tripplite.com
Tripp Lite Company's Information
Click Tripp Lite for all products
Local #: 773-869-1234
Tech Support #: 773-869-1234
Site: www.tripplite.com
Product Reviews
Overall Rating | Write a Review
|
Best Sellers
More Best Sellers
Recently Viewed
About Tripp Lite
At Tripp Lite, we believe that quality power protection and connectivity solutions are essential for businesses and individuals alike. With over 95 years of experience in the industry, we have developed a reputation for providing reliable, innovative products at affordable prices.
Why buy from Tripp Lite?
Reliability: Our products are designed and manufactured to the highest standards, ensuring they will keep your devices and systems protected and running smoothly.
Innovation: We are constantly innovating and developing new technologies to meet the changing needs of our customers.
Customer service: We pride ourselves on providing excellent customer service, with knowledgeable staff available to help you with any questions or issues you may have.
Affordable prices: We offer competitive prices without sacrificing quality, making our products a great value for your money.
Comprehensive product range: We offer a wide range of products, from surge protectors and power strips to UPS systems and connectivity solutions, to meet the needs of businesses and individuals.
About us:
Tripp Lite was founded in 1922 as a manufacturer of electrical components and has since grown into a leading provider of power protection and connectivity solutions. Our products are used by businesses, government agencies, schools and other organizations around the world.
We are committed to providing our customers with high-quality, reliable products backed by excellent customer service. We strive to be the go-to source for all your power protection and connectivity needs.
CompSource can solution sell power and Tripp Lite is one of manufacture we have a lot of knowledge and history with. Please checkout some of the most popular Tripp-Lite categories we offer;
- Tripp Lite UPS
- Tripp Lite PDUs
- Tripp Lite Surge Protectors
- Tripp Lite Rack Equipment
- Tripp Lite Video Consoles/Extenders
- Tripp Lite Power Strips
We want this to be as easy and stress-free as possible.
CompSource is here to help you decide. We have very knowledgeable sales people that will assist in your Tripp Lite UPS and power solution's. You can also Chat with us or give our professionals a quick phone call (800)-413-7361, we can assist with the best solution for your needs and budget.
Configurators
Learn more about Cooling Systems
Importance of Proper Cooling: Data centers and server closets house a significant amount of electronic equipment that generates heat during operation. Maintaining appropriate temperatures is crucial for the performance, longevity, and reliability of the equipment. Excessive heat can lead to equipment failure, reduced efficiency, and potential data loss.
Cooling Systems for Data Centers and Server Closets: a. Precision Air Conditioning (PAC): PAC systems are designed specifically for data centers and server rooms. They provide precise temperature and humidity control through advanced cooling techniques, such as direct expansion or chilled water systems. PACs offer better control, redundancy, and scalability to meet the unique cooling demands of these environments.
b. Computer Room Air Conditioning (CRAC): CRAC units are commonly used in larger data centers. They operate similarly to PAC systems but are typically larger in capacity and often incorporate additional features like hot aisle/cold aisle containment for improved efficiency.
c. In-Row Cooling: In-row cooling systems are strategically placed close to the server racks, providing localized cooling. These systems offer better efficiency, reduced energy consumption, and easier scalability.
- Factors to Consider: When selecting and implementing air conditioning for data centers and server closets, the following factors should be considered:
a. Heat Load Calculation: Accurate heat load calculation is essential to determine the cooling capacity required to maintain appropriate temperatures. Factors like equipment density, power consumption, and future growth should be considered.
b. Redundancy and Resilience: Data centers require redundancy in cooling systems to ensure uninterrupted operation. Implementing redundant systems, backup power supply, and appropriate maintenance plans are vital to avoid downtime and equipment failures.
c. Airflow Management: Proper airflow management is crucial to maximize cooling efficiency. Hot aisle/cold aisle containment, optimized rack layouts, and effective use of air distribution systems help to minimize hot spots and ensure uniform cooling.
d. Energy Efficiency: Data centers consume substantial amounts of energy, and optimizing energy efficiency is paramount. Consider energy-efficient cooling solutions, such as variable speed fans, economizers, and energy management systems, to reduce power consumption and associated costs.
- Maintenance and Monitoring: Regular maintenance and monitoring are essential for the reliable operation of cooling systems in data centers and server closets. Key practices include: a. Cleaning air filters and coils to ensure optimal airflow. b. Regular inspections for leaks, proper refrigerant levels, and electrical connections. c. Monitoring temperature and humidity levels to identify and address any anomalies promptly. d. Implementing proactive maintenance plans and partnering with qualified HVAC professionals.
Conclusion: Proper cooling is a critical aspect of maintaining optimal conditions in data centers and server closets. By understanding the specific requirements, selecting suitable cooling systems, implementing proper airflow management, and adhering to regular maintenance practices, data center operators can ensure efficient cooling, equipment reliability, and the longevity of their valuable electronic assets.
Great customer service, straight to the point. Good pricing and the delivery service was fast and they responded within 24hrs for my items, 24hrs later my items arrived! Very pleased with my items and service from CompSource. Sergio MMore Reviews